Technical data
Temperature range-25 °C ... +70 °C (process temperature)
Mountingin any position
Maintenanceno maintenance necessary

 

 

Switch variations
 KE - Limit switch
with mechanical contact
KI - Inductive
proximity switch
KN - Inductive
proximity switch NAMUR
Switching function 1 NC + 1 NOPNP, Normally Open (NO)Normally Closed (NC)
Supply voltage10 ... 30 V DC8 V DC
Capacity
of the contact
1,5 A / 250 V AC200 mA,
constant current
 
Type of protection
DIN EN 60529
IP67
IP68
IP68
Ex type of protectionex_gelb_trans.gifII 3D  T80 °C  IP67
ex_gelb_trans.gifII 3GD  EEx  nL T6
         T70 °C  IP67 
ex_gelb_trans.gifII 3D  IP68  T95 °Cex_gelb_trans.gif II 2G  EEx  ia  IIC  T6
          and
ex_gelb_trans.gif II 1D Ex  iaD 20 T...°C
Cable length2 m, 5 m and 10 m2 m, 5 m and 10 m2 m, 5 m and 10 m

More technical details

 


atex_option_dust_en.jpg
B0 = Ex type of protection of the switches KE-XCM-A110-*B0  ex_gelb_trans.gif II 3D  T 80 °C  IP67
EC-Declaration of conformity
II 3D >> Download >> KE-903


B0 = Ex type of protection of the switches KI-XCK-BI3U-7-*B0   and  
                                                                           KI-BI3U-M12AP-*B0  ex_gelb_trans.gif II 3D  IP68  T 95 °C
EC-Declaration of conformity
II 3D >> Download >> 3120M

 

B0 = Ex type of protection of all the other switches KI-...B0  ex_gelb_trans.gif II 3D  T 90 °C  IP68
EC-Declaration of conformity
II 3D >> Download >> KE-914X


atex_option_gas_dust_en.jpg
B8 = Ex type of protection of the switches KE  ex_gelb_trans.gif II 3GD  EEx  nL T6  T 70 °C  IP67
EC-Declaration of conformity
II 3GD >> Download >> KE-916X 

Ex
type of protection of the switches KN   ex_gelb_trans.gif II 2G  EEx  ia  IIC  T6   and    
                                                                          ex_gelb_trans.gif II 1D  Ex  iaD  20  T... °C