Technical data
Temperature range-25 °C ... +70 °C
Mounting position vertical, inclined and horizontal (always on top of the tube)
Maintenanceno maintenance necessary

 
 


Switch variations

SES -
Limit switch with mechanical contact
SIS -
Inductive proximity switch
SNS -
Inductive
proximity switch NAMUR
Supply voltage
10 ... 30 V DC8 V DC
Switching
function
1 NC + 1 NOPNP, Normally Open (NO)Normally Closed (NC)
Capacity
of the contact
1,5 A / 250 V AC200 mA,
constant current
 
Type of protection
DIN EN 60529
IP67IP68IP68
Ex type
of protection
ex_gelb_trans.gifII 3D  IP67  T80 °C
ex_gelb_trans.gifII 3GD  EEx  nL T6
          IP67  T72 °C

ex_gelb_trans.gifII 3D IP68  T80 °C ex_gelb_trans.gifII 2G EEx ia IIB T6 
          and 
ex_gelb_trans.gifII 2D Ex iaD  21  T67 °C
Cable length2 m, 5 m and 10 m2 m, 5 m, 10 m2 m, 5 m and 10 m


 

More technical details 
Download >> Appliance informations >> SES-GI-02
Manufacturer's declaration NR and EC-Declaration of conformity EMV >> Download >> HE-KE-004
Operating instructions >> Download >> SES-BA-01




axstaub_26px.jpg
B0 = Ex type of protection SES ex_gelb_trans.gif II 3D  IP67  T 80 °C
EC-Declaration of conformity  II 3D >> Download >> KE-904X 

B0
= Ex type of protection SlS ex_gelb_trans.gif II 3D  IP68  T 80 °C
EC-Declaration of conformity II 3D >> Download >> KE-918X


atex_option_gas_dust_en.jpg
B8 = Ex type of protection SES  ex_gelb_trans.gif II 3GD  EEx  nL T6  IP67  T 72 °C
EC-Declaration of conformity II 3GD >> Download >> KE-906X

B6 = Ex type of protection SNS ex_gelb_trans.gif II 2G  EEx  ia  IIB  T6        
                                                                   II 2D  Ex  iaD  21  T 67 °C

EC-Declaration of conformity II 2G   II 2D >> Download >> KE-919X