Page 1 of 2
Options and accessories for rotary blade level indicators
Various process connections optional in aluminium or stainless steel
Threads: in the sizes G1" G1¼" G1½" G2" M30x1.5 M32x1.5
Flanges: F70, F100, DN32, DN100
Encapsulated ball bearings
and different sealing rings
-----------------------------------------------------------------------------------------------------------------------------------
Self-monitoring
- D1 Rotation control - function monitoring
to control cable break, voltage breakdown,
motor, gear unit and if existing the
DC/AC-converter for motor voltage
- D2 Voltage monitoring
to control cable break and
voltage breakdown
Operating instructions >> Download >> DF-BA-D1
-----------------------------------------------------------------------------------------------------------------------------------
Signal delay
- D3 delay of the empty indication
- D4 delay of the full indication
-----------------------------------------------------------------------------------------------------------------------------------
D9 Rotation control - function monitoring
- Pulsating „all-right-signal“ for rotary blade level indicator DF
The „all-right-signal“ has been generated from a special stabilized sensor with a separate,
independent electronics, witch is insensitive from voltage and current alterations. The signal
has been given to the controller as a pulsating signal in timed sequence „impulse-pause“.
Therefore it’s guaranteed that a failure source can be identified without any influences of
voltage breakdown, cable break or relay defect etc.
Thereby it is guaranteed that the secure function anyway of the rotary blade level indicator DF
can be registered by the controller respectively by the process control system as a real „all-right-signal“.
Permanent impulse-pause signal as long as the rotary blade level indicator is working correctly.
No signal if there is a malfunction or a failure of the appliance.
Capacity of the contact: 200mA
available in 24 V DC only
Operating instructions >> Download >> DF-BA-D9
-----------------------------------------------------------------------------------------------------------------------------------
|
Signal lamps on top of the housing for all level indicators
|
- H0 function display with 4LEDs
| yellow LED above |
= |
"under voltage" |
| green LED above |
= |
"full" |
| green LED bottom |
= |
"empty" |
| red LED bottom |
=
|
"malfunction" (option) |
- H1function display with collar,
visible from outside
Download >> DF Appliance information >>DF-GIA-13.1
|
 |
-----------------------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------------------
-----------------------------------------------------------------------------------------------------------------------------------
<< Start < Prev 1 2 Next > End >> |